Planning the Power Supply and Sockets for a Refraction Room
A refraction room needs more sockets than its furniture suggests. The chair, tabletop and arm share one mains lead, but every instrument on the tabletop, the chart on the far wall and the practitioner’s computer each need their own. This page sets out how to count them and where to put them, using the figures published for each model.
Every wattage here is reproduced as that model’s specification states it. This page does not size circuits, fuses or cables; that is for your electrician and your local regulations.
Instruments shown on the furniture are not part of the supply unless a quotation states otherwise, so their power needs come from their own manufacturers.
Six points to settle.
1. What the published figure covers
The power figure on a product page covers the furniture only: the lift motors, the tabletop drive and the built-in lamp. It is given in different forms. The C-3, C-10A, C-12 and C-800 list 3 W under power / lighting; the HRT-1A and HRT-3 list 20 W; the MI-180, MI-5500A, TG-510, TG-1010 and TG-1100A list a total power consumption of 50 W or 100 W; the TR-500A and TR-900 list the motor and the illuminator separately, 55 W plus 40 W and 55 W plus 16 W; and the LY-177, LY-300, LY-500 and LY-700 list a maximum power of 100 W or 150 W. The TR-510 publishes no power figure. Read each as stated and ask us before relying on a figure that is not there.
2. The furniture draws little; the count matters more
Across the range, the listed figures run from 3 W to 150 W for a refraction unit and from 45 W to 120 W for an instrument table. None of these is what decides the installation. What decides it is how many separate leads will reach the wall: one for the refraction unit or the chair, one for a separate instrument table, and one for each mains-powered instrument. Count the leads, then add a spare.
3. Sockets built into the furniture
Some models carry outlets for the instruments that stand on them, which reduces the count at the wall. The LY-3BD lists three AC sockets, one on the column plus a two-outlet strip under the top. The WB-3A and WB-31ADT each list an auxiliary AC outlet beside the fused power switch. The LY-3S-1 lists a concealed power outlet and the LY-3S-1A a concealed power socket, a network port and a power inlet with an illuminated switch. The TG-510 lists a 3 V / 6 V / 12 V AC outlet on the tabletop and the TG-1010 lists 3 V / 6 V / 12 V AC outlets; these are low-voltage outlets as specified, not mains sockets. The LY-300, LY-500 and LY-700 list USB ports in the tabletop edge or control panel.
4. Where the leads go
A refraction unit stands in one place and its single lead leaves from the base, so one socket low on the wall behind the unit, or a floor box under it, keeps the lead out of the patient’s path. A separate instrument table is moved to the patient, so its socket should be on the practitioner’s side with enough slack for the table’s travel; a tabletop cable outlet, listed on the LY-3BD and the LY-3S-1A, keeps the instrument leads together. The chart, projector or screen sits on the wall the patient faces, at the far end of the room, and needs a socket there. The CH-1 practitioner stool lists a rechargeable 5.2 Ah battery and no trailing mains lead in use.
5. Voltage version and plug
Every unit, chair and table that lists a supply is specified for AC 220 V / 50 Hz or 110 V / 60 Hz, and the version is specified on the quotation. The plug type is confirmed against the quotation as well, so tell us the country of installation. Two items run on low voltage inside: the LY-177, LY-300, LY-500 and LY-700 list their lighting as DC 24 V, 3 W, and the PK-310A chair lists a 24 V DC power input. Ask us how the PK-310A is supplied before you plan its socket.
6. What to give the electrician
A sketch of the layout with the unit, the table, the chart wall and the practitioner’s desk marked; the number of leads at each position; the supply voltage you will be ordering; and the instrument manufacturers’ own power figures. Our room layout guide covers the positions; this page gives the furniture figures; the instrument figures come from their suppliers.
Published power figures.
| Model | Power as listed | Outlets and ports as listed | Supply as listed |
|---|---|---|---|
| C-3 · C-10A · C-12 · C-800 | Power / lighting 3 W | None listed | AC 220 V / 50 Hz or 110 V / 60 Hz |
| HRT-1A · HRT-3 | Power / lighting 20 W | None listed | AC 220 V / 50 Hz or 110 V / 60 Hz |
| MI-180 | Total power consumption 50 W | None listed | AC 220 V / 50 Hz or 110 V / 60 Hz |
| MI-5500A · TG-1100A | Total power consumption 100 W | None listed | AC 220 V / 50 Hz or 110 V / 60 Hz |
| TG-510 | Total power consumption 100 W | 3 V / 6 V / 12 V AC outlet on the tabletop | AC 220 V / 50 Hz or 110 V / 60 Hz |
| TG-1010 | Total power consumption 100 W | 3 V / 6 V / 12 V AC outlets | AC 220 V / 50 Hz or 110 V / 60 Hz |
| TR-500A | Motor 55 W; illuminator 40 W | None listed | AC 220 V / 50 Hz or 110 V / 60 Hz |
| TR-900 | Motor 55 W; illuminator 16 W | None listed | AC 220 V / 50 Hz or 110 V / 60 Hz |
| TR-510 | Not listed | None listed | AC 220 V / 50 Hz or 110 V / 60 Hz |
| LY-177 · LY-300 · LY-700 | Maximum power 100 W; lighting DC 24 V, 3 W | USB ports in the tabletop edge (LY-300, LY-700) | AC 220 V / 50 Hz or 110 V / 60 Hz |
| LY-500 | Maximum power 150 W; lighting DC 24 V, 3 W | USB port on the control panel | AC 220 V / 50 Hz or 110 V / 60 Hz |
| WB-3A · WB-31ADT | Total power consumption 45 W | One auxiliary AC outlet; fused power switch | AC 220 V / 50 Hz or 110 V / 60 Hz |
| LY-3AD · WB-31L10 | Maximum power 60 W (LY-3AD); total power consumption 60 W (WB-31L10) | None listed | AC 220 V / 50 Hz or 110 V / 60 Hz |
| LY-3AH | Maximum power 100 W | None listed | AC 220 V / 50 Hz or 110 V / 60 Hz |
| LY-3BD | Maximum power 100 W | 3 AC sockets; cable outlet in the tabletop | AC 220 V / 50 Hz or 110 V / 60 Hz |
| LY-3S-1 · LY-3S-1A | Maximum power 120 W | Concealed power outlet; LY-3S-1A adds a network port and a power inlet with illuminated switch | AC 220 V / 50 Hz or 110 V / 60 Hz |
| PK-310A | Not listed | None listed | 24 V DC power input |
| CH-1 stool | Not listed | None listed | Rechargeable battery, 5.2 Ah |
Figures are as each model’s specification states them; “none listed” means the product page publishes no outlet, not that there is none. The 3 V / 6 V / 12 V outlets on the TG-510 and TG-1010 are low-voltage outlets as specified. The furniture is specified for both voltage versions; the one you receive is specified on the quotation.
Using this in a plan.
Start from the layout, not the wattage. Mark where the unit or the chair will stand, where the table will travel, which wall carries the chart and where the practitioner sits, then count the leads at each of those four positions and add a spare. Put the furniture’s socket low and behind, the table’s socket on the practitioner’s side, and the chart’s socket on the far wall. Leave circuit sizing, fusing and cable routes to your electrician and your local regulations.
Tell us the country of installation and your supply voltage, and we specify the voltage version and plug type on the quotation. If you want a figure that a product page does not list, ask us for it before you plan around it.
Questions about power and sockets.
How many sockets does a refraction room need?
Count the leads: one for the refraction unit or the patient chair, one for a separate instrument table, one for each mains-powered instrument, one for the chart, projector or screen, and the practitioner’s computer and printer, then add a spare. Some tables carry their own outlets, such as the three AC sockets listed on the LY-3BD, which reduces the count at the wall.
How much power does a refraction unit use?
Little. The listed figures run from 3 W to 150 W across the range, and from 45 W to 120 W for the instrument tables. The instruments you mount have their own figures from their manufacturers.
Does a refraction unit need a dedicated circuit?
We do not specify one; the listed draw is small. Whether the room’s sockets share a circuit is for your electrician and your local regulations to decide, taking the instruments into account.
Which voltage do I order?
Each unit, chair and table is specified for AC 220 V / 50 Hz or 110 V / 60 Hz. Tell us the country of installation and we specify the version and plug type on the quotation.
Can the stool work without a mains lead?
The CH-1 practitioner stool lists a rechargeable 5.2 Ah battery and no trailing mains lead in use.
Related guides and equipment.
Tell us the country and the room.
Send the room dimensions, the instruments you will place and the country of installation. We reply with a configuration, voltage version and quotation.