Selection guide

How to Choose Refraction-Room Furniture

Five decisions settle most refraction-room specifications. Each one below is answered with the specification figures for all 34 models.

This page compares specified specification figures only. It is not clinical, architectural or compliance advice, and it does not promise a minimum room size or universal instrument compatibility. Standard and optional items, plug type and voltage version are confirmed against the quotation.

C-10A ophthalmic refraction unit — ENOCH Refraction
34
Models across three lines
400 × 480 – 600 × 1080 mm
Instrument-table tops
450 – 680 mm
Seat heights, chairs and stools
20 years
In ophthalmic equipment
Start here

Five decisions, in order.

Work through these in sequence. The first decides which of the three product lines you are shopping in; the rest narrow it to a model.

  • 1. One combined unit, or a chair and a table chosen separately?

    A refraction unit brings the chair, the phoropter arm and the instrument tabletop into a single assembly, so the refraction sequence runs without moving the patient between stations; North American practice often calls the same assembly as an ophthalmic chair and stand. There are sixteen. The alternative is to choose an instrument table and an examination chair independently — eight tables, ten chairs and stools — which gives more freedom in how the room is laid out and lets one part be changed later without the other.

  • 2. How much floor area is there?

    Among the refraction units the figures run from 940 × 800 mm for C-3, the most compact cabinet unit, to 2100 × 1200 mm for C-800 with its side cabinet. TG-510 is specified at 1750 × 2470 mm. HRT-3 specifies a 1500 × 2500 mm working footprint because its tabletop slides. Among the chairs, CH-AST is the smallest patient chair at 650 × 550 mm, while CH-3 measures 1640 × 590 mm because it travels 150 mm front to rear.

    One caution when comparing: the specifications do not all specify the same field. Some give the unit’s own dimensions, others give a space figure meaning the area to allow around it. Read those as two different measurements rather than one list, and send a room drawing before ordering. Our refraction room layout guide works through clear height, floor area and the clearances to leave around each line.

  • 3. How many instruments, and how much tabletop do they need?

    Instrument-table tops in the range run from the 400 × 480 mm footprint shared by LY-3AD and WB-3A to 600 × 1080 mm on LY-3S-1, which pairs that top with an adjustable equipment shelf. WB-31L10 sits at the wide end at 1050 × 550 mm, and WB-31ADT puts a 540 × 320 mm drawer under a 600 × 460 mm top. Load ratings run from 55 kg to 200 kg and all eight tables specify one, LY-3AH being the highest at 200 kg.

  • 4. Which movements are powered, and how far do they travel?

    Among the refraction units the specified tabletop lift travel is 270 mm on TG-1010, 200 mm on MI-180, 120 mm on MI-5500A and 100 mm on HRT-3. The instrument tables specify height ranges instead: 630–800 mm on LY-3AD, 630–820 mm on LY-3AH, 660–860 mm on WB-31L10 and 680–880 mm on LY-3S-1.

    For seating, specified seat heights span 450–680 mm across the line, from 450–550 mm on the CH-1 practitioner stool up to 680 mm on CH-10A and CH-8. Read the travel figures carefully: CH-3 specifies 150 mm of front-to-rear travel, while MC-N and PK-310A specify 150 mm of powered lift travel. Those are not the same movement.

  • 5. What supply voltage, and which plug?

    Supply voltage is built to order across the range — 110 V and 220 V are both available on any model. The one exception is PK-310A, whose drive is 24 V DC. Tell us the destination country and the voltage version and plug type are set on the quotation.

Decision table

Where to look first.

A shortcut through the five questions above. The models named are representative starting points, not the only options — each category page carries the full list with specification figures side by side.

If this is your situationLook atRepresentative models
Small room, one refraction laneThe most compact refraction unitsC-3, MI-180
Two instruments on the same laneUnits with two instrument positionsHRT-1A, HRT-3
Storage matters in the roomUnits with drawers or a side cabinetTG-1010, C-800, WB-31ADT
Stored height positions for several operatorsTouch-control unitC-10A
Chair and table specified separatelyAn instrument table plus an examination chairWB-31L10, CH-10A
Heavy instrument on the tableTables with a specified load ratingLY-3AH (200 kg), LY-3S-1 (120 kg)
110 V / 60 Hz supplyBuilt to order on any model—
Smallest chair footprintCompact patient chairCH-AST
Patient moved to the instrumentChair with front-to-rear travelCH-3
Seating for the practitionerOptometrist stoolCH-1

Scroll the table sideways to see every column.

Before you ask for a quotation

What the specification does not settle.

Standard and optional items, plug type and voltage version are confirmed against the quotation.

Diagnostic instruments shown in product photography illustrate use and are not part of the furniture supply scope unless a quotation states otherwise.

Standard warranty is 12 months from delivery. Within that period ENOCH supplies the replacement parts needed for any fault not caused by misuse or accidental damage.

Every dimension, travel figure, load rating and colour on this site is the specification value for that model. Where a figure is not specified, the field is left empty rather than estimated.

Common questions

Questions we get before the first order.

Is a combined unit or a separate chair and table the better buy?

Neither is universally cheaper — it depends on the room. A combined unit puts the chair, the arm and the tabletop in one assembly, so the patient stays in place through the refraction sequence. Choosing separately lets you match the tabletop to the instruments you already own, place the chair where the room allows, and change one part later without the other. If floor area is tight and the room runs a single refraction lane, start with the units; if the room is irregular or the instrument set unusual, start with the tables and chairs.

What should I measure before ordering?

Three things settle most specifications: the clear floor area for the unit or chair, including the room a sliding tabletop or a travelling chair needs; the working height your operators want, against the height ranges; and the footprint and weight of every instrument that has to sit on the tabletop. Send a room drawing with those and we will check them against the figures before quoting. How to measure the room sets out the order to take those figures in, starting with the clear ceiling height.

Are the instruments included?

No. Every figure on this site describes furniture. Diagnostic instruments shown in product photography illustrate use and are not part of the supply scope unless a quotation states otherwise.

Can I get a 110 V version?

Yes. Supply voltage is built to order across the range — 110 V and 220 V are both available. Tell us the destination country and the voltage version and plug type are set on the quotation rather than assumed here.

How many models should I shortlist?

Two or three within one line is usually enough. The models in each line differ mainly in dimensions, in how much of the movement is powered, and in storage — so once the floor area and the instrument list are fixed, most of the range rules itself out. The comparison table on each category page is laid out for exactly that.

Tell us the room and the instruments.

Send your dimensions, quantity and destination. You will get a written configuration, lead time and quotation — usually within one business day.