Product line

Ophthalmic Refraction Units

Combined refraction workstations — examination chair, instrument swing arm and instrument tabletop assembled as one unit.

A refraction unit brings the chair, the phoropter arm and the instrument tabletop into a single assembly, so the refraction sequence runs without moving the patient between stations. North American practice often refers to the same assembly as a chair unit, or as an ophthalmic chair and stand. European buyers ask for the same thing as a refractie unit in the Netherlands and as a riunito oculistico in Italy. The sixteen models below differ mainly in how much of that movement is powered, how the instrument surfaces are arranged, and how much floor area the unit needs. Specification figures are reproduced exactly as documented.

C-10A Refraction Unit — ENOCH Refraction
16
Models in this line
840 – 1070 mm
Main tabletop widths (14 models)
110 / 220 V
Supply voltage, built to order
20 years
In ophthalmic equipment
Choosing

How the sixteen models differ.

Four practical questions usually decide which unit fits a room. Answer them first and the list below narrows quickly. If you are still weighing a combined unit against a separate chair and table, start with the selection guide.

  • How much of the movement is powered

    Some units drive the chair, the swing arm and the tabletop independently; others power one axis and leave the rest manual. More powered axes shorten the sequence between instruments; fewer keep the unit simpler to service.

  • How the instrument surfaces are arranged

    A single main tabletop suits one or two instruments in a fixed position. A main tabletop plus a rotating or sliding secondary surface lets a second instrument stay mounted without crowding the working area.

  • Floor area and how the room opens

    Specified overall dimensions are for the unit at rest. A sliding tabletop or a reclining chair needs clearance beyond that figure, so the swept area matters more than the footprint in a narrow room. Our room layout guide sets out those clearances, and the clear ceiling height to check before anything else.

  • Storage and cabling

    Drawer sizes vary from a single wide front drawer to a column of smaller vertical drawers. Tell us which instruments will be mounted and we will check drawer clearance and cable routing against the drawing before quotation.

The line

16 models.

Every model uses its original model number. Open a model for the full specification table and what is included in the furniture supply scope.

C-10A Refraction Unit — ENOCH Refraction
C-10A

Touch control with four stored patient-height positions

Main tabletop: 1010 × 480 mmOverall dimensions: 1050 × 1300 × 1550 mm
View specifications →
C-12 Refraction Unit — ENOCH Refraction
C-12

Powered instrument tray with fold-away controls

Main tabletop: 1070 × 490 mmOverall dimensions: 1100 × 1300 × 1550 mm
View specifications →
C-800 Refraction Unit — ENOCH Refraction
C-800

Side cabinet with rotating auxiliary surface

Overall dimensions: 2100 × 1200 × 1700 mmChair height: 500–680 mm
View specifications →
C-3 Refraction Unit — ENOCH Refraction
C-3

Compact cabinet unit with screw-lift swing arm

Main tabletop: 900 × 460 mmOverall dimensions: 940 × 800 × 1850 mm
View specifications →
HRT-1A Refraction Unit — ENOCH Refraction
HRT-1A

Two-instrument layout with powered sliding tabletop

Main tabletop: 965 × 385 mmOverall dimensions: (1470–1620) × (1020–1360) × 1900 mm
View specifications →
HRT-3 Refraction Unit — ENOCH Refraction
HRT-3

Two instrument positions with a reclining, sliding chair

Main tabletop: 985 × 410 mmOverall dimensions: 1650 × 1050 × 1900 mm (tabletop not extended)
View specifications →
MI-5500A Refraction Unit — ENOCH Refraction
MI-5500A

Metal body with ambient lighting

Main tabletop: 1070 × 500 mmOverall dimensions: 1190 × 1300 × 1750 mm (space dimensions)
View specifications →
MI-180 Refraction Unit — ENOCH Refraction
MI-180

Open-frame workstation

Main tabletop: 900 × 500 mmOverall dimensions: 900 × 1000 × 1700 mm (space dimensions)
View specifications →
TG-1010 Refraction Unit — ENOCH Refraction
TG-1010

Tall column with vertical drawer storage

Main tabletop: 890 × 430 mmDrawer, internal: 190 × 245 × 75 mm
View specifications →
TG-510 Combined Refraction Table — ENOCH Refraction
TG-510

Compact combined table with an electric lift chair

Main tabletop: 950 × 445 mmOverall dimensions: 1750 × 2470 × 2060 mm
View specifications →
TR-500A Refraction Unit — ENOCH Refraction
TR-500A

2130 mm overall height, 840 mm tabletop

Main tabletop: 840 × 405 mmOverall dimensions: 1510 × 1000 × 2130 mm
View specifications →
TR-510 Refraction Unit — ENOCH Refraction
TR-510

Powered chair, movable tabletop and overhead lamp

Powered patient chairMovable instrument tabletop
View specifications →
TR-900 Refraction Unit — ENOCH Refraction
TR-900

1990 mm overall height, 840 mm tabletop

Main tabletop: 840 × 405 mmOverall dimensions: 1500 × 1000 × 1990 mm
View specifications →
LY-500 Compact Refraction Unit — ENOCH Refraction
LY-500

Motorized two-instrument tabletop with a manual swing arm

Tabletop: 960 × 400 mmFootprint: 1100 × 1500 mm
View specifications →
LY-700 Motorized Refraction Unit — ENOCH Refraction
LY-700

Two-surface workstation with trial-lens drawers

Large tabletop: 1060 × 490 mmUnit: 1070 × 1000 × 1670 mm
View specifications →
LY-177 Refraction Unit — ENOCH Refraction
LY-177

Sport-style patient chair with a lifting instrument arm

Large tabletop: 1060 × 495 mmUnit: 1080 × 1070 × 1620 mm
View specifications →
Comparison

Specifications, side by side.

Figures below are the specification values for each model. A blank cell means that figure is not specified for that model — we do not estimate it. Open a model for its full specification table and the source note behind each figure.

ModelMain tabletopOverall dimensionsChair heightDrawer, internalPower supply
C-10A1010 × 480 mm1050 × 1300 × 1550 mm500–680 mm530 × 380 × 65 mm220 V / 50 Hz
C-121070 × 490 mm1100 × 1300 × 1550 mm500–680 mm540 × 340 × 55 mm220 V / 50 Hz
C-800—2100 × 1200 × 1700 mm500–680 mm550 × 330 × 50 mm220 V / 50 Hz
C-3900 × 460 mm940 × 800 × 1850 mm500–680 mm—220 V / 50 Hz
HRT-1A965 × 385 mm(1470–1620) × (1020–1360) × 1900 mm550–650 mm480 × 350 × 60 (125) mm220 V / 50 Hz
HRT-3985 × 410 mm1650 × 1050 × 1900 mm (tabletop not extended)550–650 mm495 × 360 × 80 mm220 V / 50 Hz
MI-5500A1070 × 500 mm1190 × 1300 × 1750 mm (space dimensions)—540 × 390 × 60 mm; small drawer 250 × 180 × 70 mm220 V / 50 Hz
MI-180900 × 500 mm900 × 1000 × 1700 mm (space dimensions)—545 × 370 × 50 mm220 V / 50 Hz
TG-1010890 × 430 mm2330 × 1300 × 2090 mm—190 × 245 × 75 mm220 V / 50 Hz
TG-510950 × 445 mm1750 × 2470 × 2060 mm——220 V / 50 Hz
TR-500A840 × 405 mm1510 × 1000 × 2130 mm460–600 mm—110 V / 220 V
TR-510————AC 220 V / 50 Hz or 110 V / 60 Hz (specified on the quotation)
TR-900840 × 405 mm1500 × 1000 × 1990 mm460–600 mm—110 V / 220 V
LY-500960 × 400 mm1100 × 1500 × 1800 mm510–660 mm540 × 360 × 60 mm; 540 × 360 × 70 mmAC 220 V / 50 Hz or 110 V / 60 Hz (specified on the quotation)
LY-7001060 × 490 mm1070 × 1000 × 1670 mm500–650 mm540 × 380 × 60 mm; small drawers 270 × 185 × 40 mm; 270 × 185 × 60 mmAC 220 V / 50 Hz or 110 V / 60 Hz (specified on the quotation)
LY-1771060 × 495 mm1080 × 1070 × 1620 mm520–670 mm540 × 380 × 60 mm; small drawers 270 × 185 × 40 mm; 270 × 185 × 60 mmAC 220 V / 50 Hz or 110 V / 60 Hz (specified on the quotation)

Scroll the table sideways on a narrow screen.

Supply scope

What is included.

Furniture supply scope

Diagnostic instruments shown in product photography — phoropters, chart projectors, autorefractors, slit lamps — illustrate use and are not part of the furniture supply scope unless a quotation states otherwise.

Standard and optional items, plug type and voltage version are confirmed against the quotation for each order. Standard warranty is 12 months from delivery. Within that period ENOCH supplies the replacement parts needed for any fault not caused by misuse or accidental damage.

Prices are quoted per configuration. Send the room dimensions and the instruments to be mounted and we will come back with a configuration and a quotation.

Questions

Common questions.

What is a refraction unit?

A refraction unit is a single powered workstation that carries the refraction instruments and the patient chair on one frame, so the examination sequence happens without moving the patient between stations. The unit supplies the tabletop, column, powered lift, instrument arm, lighting and chair. The diagnostic instruments themselves are separate. When comparing ophthalmic units, check which movements and furniture components are specified for each model.

How much floor space does a refraction unit need?

Among models with published dimensions, the space figures run from 940 × 800 mm (C-3) to 1750 × 2470 mm (TG-510), with overall heights of 1550–2130 mm. HRT-1A is specified as a range, (1470–1620) × (1020–1360) mm, because its tabletop extends. TG-1010 overall dimensions are confirmed as 2330 × 1300 × 2090 mm (L × W × H).

Are the diagnostic instruments included?

No. Phoropters, chart projectors, autorefractors and slit lamps shown in product photography illustrate use and are not part of the furniture supply scope unless a quotation states otherwise. Tell us which instruments you intend to mount and the fit is checked against the drawing before quoting.

What voltage do they run on?

Supply voltage is built to order: 110 V and 220 V are both available on any model in this line. Voltage and plug version are confirmed against the quotation for each order — tell us the destination country and the unit is specified accordingly.

What working heights do they reach?

Fixed tabletop heights, motorized tabletop height ranges, and chair-seat heights are separate figures. Where a fixed tabletop height is published: LY-700 870 mm, LY-500 920 mm. Where a motorized tabletop height range is published (floor to tabletop), examples include bands around 660–910 mm such as LY-177 at 790–910 mm; check each model. Chair-seat ranges in the comparison table span about 460–680 mm across models. Blank cells mean that figure is not specified for that model.

Tell us the room and the instruments.

Send the room dimensions, the instruments to be mounted and the destination market, and we will come back with a configuration, lead time and quotation.